Introduction

RADIANT INSTALLATION PANELS

paineis2

Below, we present models, sizes and further technical specifications of radiant panels shown in previous systems: radiant ceiling panels with (PYL) laminated gypsum (continuous finishes); Cuadro modular panels (false or dismountable ceiling) and drywall (PYL) radiant panels. The different references make a complete range of solutions that optimize material use. This modularity makes installation adjustment to room geometry easy and allows obtaining the required active surface with minimum possible parts, that can be translated into an important cost reduction and less time needed to finish installation.


paineis3

Becli offers different heating and cooling solutions through walls and ceilings.

Main advantages from this installations are:

– Reduced thermal inertia: once the system is working, radiant walls and ceilings almost immediately emit heat to solid items that surround them, so the room will increase its temperature quickly. Minimum distance between pipes and the external part of the radiant surface allows a faster energy interchange in this kind of climatization. When compared with radiant floor systems, at the same circuit fluid temperature, interchange surface at walls or ceilings will present a higher temperature variation, getting a greater yield in less time.

-More comfortable environments: human body grows vertically, so the radiation best received is the one that gets to it perpendicularly, like received from a wall. A wall can emit or absorb heat, has it becomes part of the radiant system, or by interchange with other bodies that surround it like floor or ceiling. Logically, also influences the thermal gains and losses that can be received from outside.


paineis4

– Cooling ability: ceiling and wall panels and the needed system adaptations allow the refresh in summer, making cold water circulate through piping (important: to avoid condensation, there is the need to control room humidity)

– Heat transfer with less obstacles: ceiling panel will not difficult room decoration. It does not impose object placing or machines in the space for system to work.

– Ideal for rebuild: this kind of use presents a great advantage so there is no need to intervene in the building floor. Masonry works almost disappear.

1200x2000mm radiant panel

Description

Wall or ceiling radiant panel, made with a 1200 x 2000 x 15 mm thick laminated gypsum board (standard sizes), where were inserted two spiral shape Ф8×1 mm  PE-Xa pipe circuits, with 5 cm technical step. Insulation is placed in the rear surface: expanded polystyrene EPS 200.

Radiant system consists in two spiral shape circuits, with 5 cm technical step. Design form was made to grant most uniform possible heat distribution. The panel can be used either for heating or cooling.

Technical Data

TECHNICAL SPECIFICATIONS

Insulation thickness30mm
Total thickness45mm
Pipe diameter8x1mm
Thermal resistance0,90m² K/W
Weight29 kg

SIZE

Panel size1200x2000 mm
Panel useful size1200x2000 mm
Panel useful surface2,4m²

1200x1000mm radiant panel

paineis4

Description

Wall or ceiling radiant panel, made with a 1200 x 1000 x 15 mm thick laminated gypsum board (standard sizes), where were inserted two spiral shape Ф8×1 mm  PE-Xa pipe circuits, with 5 cm technical step. Insulation is placed in the rear surface: expanded polystyrene EPS 200.

Radiant system consists in two spiral shape circuits, with 5 cm technical step. Design form was made to grant most uniform possible heat distribution. The panel can be used either for heating or cooling.

Technical Data

TECHNICAL SPECIFICATIONS

Insulation thickness30mm
Total thickness45mm
Pipe diameter8x1mm
Thermal resistance0,90m² K/W
Weight14 kg

Panel size1200x1000 mm
Panel useful size1200x1000 mm
Panel useful surface1,2m²

1200x500mm radiant panel

Description

Wall or ceiling radiant panel, made with a 1200 x 500 x 15 mm thick laminated gypsum board (standard sizes), where were inserted two spiral shape Ф8×1 mm  PE-Xa pipe circuits, with 5 cm technical step. Insulation is placed in the rear surface: expanded polystyrene EPS 200.

Radiant system consists in two spiral shape circuits, with 5 cm technical step. Design form was made to grant most uniform possible heat distribution. The panel can be used either for heating or cooling.

Technical Data

TECHNICAL SPECIFICATIONS

Insulation thickness30mm
Total thickness45mm
Pipe diameter8x1mm
Thermal resistance0,90m² K/W
Weight7 kg

SIZE

Panel size1200x500 mm
Panel useful size1200x500 mm
Panel useful surface0,60m²

1200x2000mm insulated closing panel

Description

Panel made with laminated gypsum board, 1200x2000x15mm standard size, glued to expanded polystyrene EPS 200insulation in the posterior part .

TECHNICAL SPECIFICATIONS

Insulation thickness30mm
Total thickness45mm
Thermal resistance0,90m² K/W
Weight26 kg

SIZE

Panel size1200x2000 mm
Panel useful size1200x2000 mm
Panel useful surface2,4m²

Radiant ''Cuadro''

RADIANT CUADRO  ALU-LR

paineis11

Suitable for heating and cooling radiant systems. It is used as finishing panel in the dismountable ceiling systems.

Outer and visible surface presents a white flat lacquered aluminium finish. Inside, a coiled 8×1 pipe integrated in other aluminium sheet, that is fastened to a 30mm rock wool cover.

TECHNICAL SPECIFICATIONS

Insulation thickness30mm
Total thickness45mm
Thermal resistance0,90m² K/W
60x60cm panel weight2,9 kg
120x60cm panel weight5,1

RADIANT CUADRO  PYL-EPS

paineis12Composition:

1) (ALU -LR) Rockwool insulation, intermediate aluminium sheet with 8×1 PE-X pipe, finishing with aluminium lacquered sheet

2)(PYL-EPS) EPS 200 Expanded polystyrene insulation, 10×1.2 PE-X pipes and laminated gypsum board

TECHNICAL SPECIFICATIONS

Insulation thickness30mm
Total thickness45mm
Thermal resistance0,78m² K/W
60x60cm panel weight3,3 kg
120x60cm panel weight6 kg

Closing ''Cuadro''

Closing panels

ALU-LR closing panels
1200×600 – 600×600

paineis13

Closing panel for radiant heating and cooling systems; it is used as finishing element for ceilings. Visible on the outside has a flat aluminium lacquered sheet. The panel itself has a 30mm rock wool cover.

TECHNICAL SPECIFICATIONS

Insulation thickness30mm
Total thickness45mm
Thermal resistance0,85m² K/W
60x60cm panel weight2,9 kg
120x60cm panel weight5,1 kg

RADIANT CUADRO PYL-EPS
1200×600 – 600×600

paineis14

Closing panel for radiant heating and cooling systems; it is used as finishing element for ceilings. Visible on the outside has a flat drywall with white vinyl. The panel itself has a 30mm EPS 200 cover.

TECHNICAL SPECIFICATIONS

Insulation thickness30mm
Total thickness45mm
Thermal resistance0,90m² K/W
60x60cm panel weight2,8 kg
120x60cm panel weight5 kg